Back to top
Thermal Conductivity of Insulating Powder
Thermal Conductivity of Insulating Powder

Thermal Conductivity of Insulating Powder

MOQ : 10 Units

Thermal Conductivity of Insulating Powder Specification

  • Voltage
  • 230 Volts
  • Power Consumption
  • 500 Watts Approx.
  • Power Supply
  • 230 V AC, 50 Hz
  • Usage
  • Pharmaceutical Equipment
  • Product Type
  • Thermal Conductivity
  • Material
  • Metal
  • Size
  • Standard Laboratory Size
  • Style
  • Table Top Model
  • Weight
  • 8-10 kg
  • Feature
  • Easy to Operate
  • Color
  • Brown
  • Test Method
  • Lees Disc Method, Radial Heat Flow Method
  • Measurement Range
  • 0.02 to 0.2 W/mK
  • Accuracy
  • 1% of reading
  • Heating Element Type
  • Nichrome Wire
  • Compliance
  • ISI Standards / As per physics laboratory experiment requirements
  • Application
  • Measurement of thermal conductivity of loose insulating powders
  • Core Pipe Material
  • Brass / Copper
  • Sample Holder Capacity
  • Single Sample
  • Temperature Sensor
  • Thermocouples (K Type)
  • Display Type
  • Analog / Digital
  • Accessories Supplied
  • Powder Sample, Power Cord, Instruction Manual
 

Thermal Conductivity of Insulating Powder Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 10 Units Per Day
  • Delivery Time
  • 2-3 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Box
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Central America, Africa, Middle East, South America, Asia
  • Main Domestic Market
  • All India
 

About Thermal Conductivity of Insulating Powder



Explore the sublime Thermal Conductivity of Insulating Powder apparatus-a hot deal for laboratories seeking accuracy and operational excellence. This special tabletop model features a lustrous brass or copper core pipe, measuring thermal conductivity from 0.02 to 0.2 W/mK with 1% precision. Equipped with both analog and digital displays, it's engineered for ease of use and optimal results. Ideal for testing a single sample of loose insulating powder, it comes complete with sample, power cord, and instruction manual. ISI compliant, this device is excellent for educational and pharmaceutical settings.

Exceptional Features and Competitive Edge

The Thermal Conductivity of Insulating Powder device boasts a sturdy metal construction and brown finish, designed specifically for standard laboratory sizes. It's widely used in pharmaceutical equipment testing, academic experiments, and industrial quality control. Competitive advantages include its easy operation, accurate results via Lee's Disc and Radial Heat Flow Methods, and durable Nichrome wire heating element. With a single-sample capacity and ISI compliance, it stands out as a reliable instrument for precise thermal conductivity assessment.


Flexible Payment & Delivery Solutions

Enjoy flexible payment terms to suit any buyer-whether you are a distributor, exporter, manufacturer, supplier, or trader across India. We offer competitive FOB port options and express shipping, ensuring prompt domestic market delivery and secure freight handling. Sample units are available upon request for evaluation prior to large orders. Our streamlined order process guarantees hassle-free transactions and speedy dispatch, making this an excellent choice for reliable laboratory equipment procurement.


FAQ's of Thermal Conductivity of Insulating Powder:


Q: How is the Thermal Conductivity of Insulating Powder apparatus operated?

A: The device is easy to operate-simply insert the powder sample into the single sample holder, set the required parameters, and use either the analog or digital display to accurately measure thermal conductivity using Lee's Disc or Radial Heat Flow methods.

Q: What materials are used for the core pipe and heating element?

A: The core pipe is made from lustrous brass or copper, and the heating element utilizes durable nichrome wire for consistent and reliable performance during each test.

Q: Where can this equipment be utilized?

A: It's ideal for physics laboratories, pharmaceutical equipment testing, and any application that requires precise measurement of the thermal conductivity of loose insulating powders.

Q: What accessories are supplied with the product?

A: The package comes with a powder sample, power cord, and a comprehensive instruction manual to facilitate immediate use upon delivery.

Q: What are the power requirements for this tabletop model?

A: The apparatus operates on a standard 230 V AC, 50 Hz power supply with an approximate power consumption of 500 watts, suitable for most laboratory environments.

Q: What is the main benefit of using this apparatus?

A: Its main advantage is delivering highly accurate and repeatable measurements, enabling users to efficiently evaluate the insulating properties of various powders with ease.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmacy Equipment Category

Shaking Machine Wrist Action

Shaking Machine Wrist Action

Price 2500 INR

Minimum Order Quantity : 10 Units

Voltage : 220240 Volt (v)

Material : Stainless Steel

Product Type : Shaking Machine

Color : Blue

Digital Electrophoresis Power Supply

Digital Electrophoresis Power Supply

Price 4000 INR

Minimum Order Quantity : 1 , , Unit

Voltage : 240 Volt (v)

Material : Stainless Steel

Product Type : Digital

Color : White

Spectro Double Polisher Machine

Spectro Double Polisher Machine

Price 2800 INR

Minimum Order Quantity : 1 Unit

Voltage : 240 Volt (v)

Material : Stainless Steel

Product Type : Spectro Machine

Color : Purple

Cam Analysis Apparatus

Cam Analysis Apparatus

Price 2500 INR

Minimum Order Quantity : 1 Unit

Voltage : 210 Volt (v)

Material : Stainless Steel

Product Type : Cam Analysis

Color : Purple