Back to top
Microbial Air Monitoring System
Microbial Air Monitoring System

Microbial Air Monitoring System

MOQ : 10 Units

Microbial Air Monitoring System Specification

  • Equipment Type
  • Microbial Air Monitoring System
  • Response Time
  • Instantaneous
  • Accuracy
  • 5%
  • Voltage
  • 220 Volt (v)
  • Port Size
  • Standard inlet 25 mm
  • Application
  • Environmental monitoring, Clean rooms, Pharma labs, Hospitals
  • Max Height
  • 300 mm
  • Measuring Range
  • 1-9999 liters
  • Features
  • Portable, Battery Back-up, Data Storage
  • Specimen Size
  • 90 mm Petri dish / 55 mm contact plate
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • Atmospheric
  • Automation Grade
  • Semi-Automatic
  • Color
  • Gray and Blue
  • Interface Type
  • USB / RS232
  • Mounting Type
  • Tabletop / Portable
  • Resolution
  • 1 L/min
  • Dimension (L*W*H)
  • 130 x 170 x 300 Millimeter (mm)
  • Operating Voltage
  • 220 V
  • Display Type
  • Digital LCD
  • Power Supply
  • 110-240 V AC, 50/60 Hz
  • Humidity
  • 10% to 90% RH
  • Power
  • 110-240
  • Number of Specimens
  • 1
  • Product Type
  • Microbial Air Monitoring System
  • Test Range
  • 1 9999 L
  • Temperature
  • 5C to 40C
  • Usage
  • Airborne microbial analysis
  • Capacity
  • 24 hours continuous operation
  • Machine Weight
  • 3.2 kg
  • Test Speed
  • Up to 100 L/min
  • Control Mode
  • Automatic / Manual
  • Noise Level
  • Less than 60 dB
  • Flow Calibration
  • Factory calibrated, EN ISO 14698-1
  • Material of Construction
  • Anodized aluminum
  • Battery Operation
  • Rechargeable Li-ion, 8 hours
  • Petri Dish Compatibility
  • 90 mm standard
  • Alarm
  • End of sampling
  • Data Storage
  • 50 sampling records
  • Weight Without Battery
  • 2.6 kg
 

Microbial Air Monitoring System Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 10 Units Per Day
  • Delivery Time
  • 2-3 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Box.
  • Main Export Market(s)
  • Western Europe, Australia, Eastern Europe, Africa, Middle East, South America, Asia, Central America, North America
  • Main Domestic Market
  • All India
 

About Microbial Air Monitoring System



Experience the splendiferous performance of our Microbial Air Monitoring System, a cutting-edge solution designed for environmental monitoring, clean rooms, pharmaceutical labs, and hospitals. In demand for its compatibility with 90 mm standard Petri dishes, it delivers enlightened precision with 5% accuracy and instantaneous response. Personalise your monitoring with automatic and manual control modes. Built with the finest anodized aluminum and offering 24-hour operation, this portable system features data storage, battery backup, and competitive pricing-making it a prime choice for distributors, exporters, manufacturers, and traders across India.

Extensive Applications and Commercial Versatility

The Microbial Air Monitoring System is used extensively in environmental monitoring, clean rooms, pharma labs, and hospitals. It is engineered for airborne microbial analysis, supporting high-accuracy measurement and reliable data collection. Used as a vital tool for sterile environments, this device finds commercial uses in pharmaceutical manufacturing, hospital infection control, and research laboratories. Its semi-automatic operation, portability, and robust design make it an essential asset for any professional concerned with environmental microbiology.


Global Export Market Reach and Flexible Payment Options

Our Microbial Air Monitoring System is shipped to prominent export markets throughout Asia, the Middle East, and Europe. We offer flexible payment terms tailored to client needs, ensuring smooth commercial transactions. FOB Port options are available on request, providing streamlined logistics for international customers. As leading exporters and suppliers, we are committed to offering timely delivery, competitive pricing, and exceptional customer support for all shipments and business collaborations worldwide.


FAQ's of Microbial Air Monitoring System:


Q: How is the Microbial Air Monitoring System used for airborne microbial analysis?

A: This system samples air using a 90 mm standard Petri dish or a 55 mm contact plate to collect airborne microorganisms. After sampling, plates are incubated to analyze microbial loads, commonly for quality control in clean rooms and pharmaceutical labs.

Q: What are the key features that make this system suitable for commercial and hospital environments?

A: The system operates continuously for up to 24 hours, has factory-calibrated flow, accurate digital LCD display, low noise, and stores up to 50 records. Its automatic/manual modes and robust portable design ensure it meets high commercial and hospital standards.

Q: Where can the Microbial Air Monitoring System be installed or used?

A: It is designed for tabletop installation or portable use in environments such as laboratories, pharmaceutical clean rooms, hospital wards, and environmental monitoring stations.

Q: What is the process for calibration and maintenance of the system?

A: The unit arrives factory-calibrated in accordance with EN ISO 14698-1, minimizing setup time. Maintenance simply involves periodic cleaning, battery checks, and ensuring petri dishes or plates are replaced as required.

Q: What benefit does the data storage feature provide to users?

A: The ability to store up to 50 sampling records enables users to easily track, review, and analyze historical data, which is essential for regulatory compliance, audits, and quality control processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory and Scientific Equipment Category

Stopper Solid Penny Head

Stopper Solid Penny Head

Minimum Order Quantity : 10 Units

Mounting Type : Pushfit

Power Supply : 220V AC

Operating Voltage : 220V

Equipment Type : Laboratory Stopper

Usage : Lab glassware sealing

Tissue Culture Microscope

Tissue Culture Microscope

Minimum Order Quantity : 10 Units

Mounting Type : Tabletop

Power Supply : 110V/220V AC, 50/60Hz

Operating Voltage : 110V/220V

Equipment Type : Tissue Culture Microscope

Usage : industrial

Magnetic Field

Magnetic Field

Minimum Order Quantity : 10 Pieces

Mounting Type : Tabletop

Power Supply : AC 220V, 50Hz

Operating Voltage : 220V AC

Equipment Type : Digital Magnetic Field Tester

Usage : Magnetic field intensity measurement

Lensometer Model no DLM 10

Lensometer Model no DLM 10

Minimum Order Quantity : 10 Pieces

Mounting Type : Bench Top

Power Supply : 230V AC, 50Hz

Operating Voltage : 230 V AC

Equipment Type : Manual Lensometer

Usage : Lens measurement in optical shops and laboratories