Michelson Interferometer (Bread Board Model) - Coherent Length of the Laser Specification

  • Temperature
  • 15C - 35C
  • Response Time
  • Immediate, manually observed
  • Power Supply
  • 220V AC, 50 Hz
  • Power
  • 220 Volt (v)
  • Product Type
  • Michelson Interferometer
  • Features
  • Laser mount, movable mirrors, breadboard, adjustable arms
  • Display Type
  • Scale and vernier; visual fringe count
  • Mounting Type
  • Tabletop (Breadboard)
  • Accuracy
  • 1 m (Mirror Movement)
  • Test Range
  • Interference Pattern Measurement
  • Color
  • White and Gray
  • Operating Voltage
  • 220V AC, 50 Hz
  • Specimen Size
  • Standard Laser Beam Spot
  • Interface Type
  • Manual Controls
  • Voltage
  • 110 Volt (v)
  • Max Height
  • Approx. 200 mm (mirror stand)
  • Automation Grade
  • Manual
  • Frequency
  • 50 Hz
  • Port Size
  • Standard Optical Mounts
  • Resolution
  • 0.01 mm (Micrometer Movement)
  • Measuring Range
  • Up to several mm (laser dependent)
  • Humidity
  • < 80% RH, non-condensing
  • Application
  • Measurement of Coherent Length of Laser (Physics Laboratory use)
  • Number of Specimens
  • Single (Interferometer setup)
  • Usage
  • Educational / Laboratory
  • Machine Weight
  • Approx. 10 kg
  • Test Speed
  • Manual adjustment
  • Test Width
  • Breadboard: 300 mm x 450 mm (approx.)
  • Test Stroke
  • Up to 25 mm (Mirror displacement)
  • Control Mode
  • Manual
  • Surface Finish
  • Matte, non-reflective breadboard
  • Equipment Type
  • Michelson Interferometer (Bread Board Model)
  • Optical Components
  • High quality front surface mirrors, beam splitter, and laser mount
  • Mirror Adjustment
  • Fine micrometer screw-driven adjustment
  • Laser Compatibility
  • Suitable for He-Ne and diode lasers
  • Anti-Vibration
  • Yes, anti-vibration rubber feet
  • Coherent Length Measurement
  • Designed specifically for measuring the coherence length of lasers
  • Material
  • Anodized aluminum breadboard, stainless steel components
  • Included Accessories
  • Laser mount, beam splitter, alignment tools, instructional manual
  • Dimension
  • Breadboard 300 x 450 mm (approx.), total setup space may vary
 

Michelson Interferometer (Bread Board Model) - Coherent Length of the Laser Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash Advance (CA), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque
  • Supply Ability
  • 10 Units Per Day
  • Delivery Time
  • 2-3 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Box.
  • Main Export Market(s)
  • Western Europe, Central America, Eastern Europe, Africa, Middle East, South America, Australia, Asia, North America
  • Main Domestic Market
  • All India
 

About Michelson Interferometer (Bread Board Model) - Coherent Length of the Laser



Unlock wondrous precision with our best-seller: the Michelson Interferometer (Bread Board Model), Laureate among laboratory instruments for laser coherence length measurement. Engineered with first-class, high-quality optical components-front surface mirrors, beam splitter, and anodized aluminum breadboard-this setup guarantees reliable measurements for He-Ne and diode lasers. Enjoy effortless alignment using the included fine micrometer adjustments and instructional manual. The anti-vibration feet and matte finish ensure stability and accurate results. Don't miss this exclusive deal-shop now for your laboratory's essential, trusted Michelson Interferometer setup!

Application Method & Usage in Academic Settings

The Michelson Interferometer (Bread Board Model) is expertly tailored for measuring the coherence length of lasers in physics laboratories. Ideal for manual, tabletop operation, the instrument comes with a detailed instructional manual for seamless setup and calibration. This apparatus is primarily used for educational demonstrations and academic research, with the site of application being laboratory environments. Controls and adjustments are accessible, fostering experiential learning and precise experimentation for students and researchers alike.


Export Markets & Shipping Policies

Serving global demand as a distributor, exporter, and supplier from India, this Michelson Interferometer is available for drop-off and express shipping to North America, Europe, Asia, and beyond. Sample policies accommodate academic institutions, with lead times estimated based on order size. Fast delivery and express shipping options allow expedited access-ensuring minimal delays from point of order to laboratory installation. Contact our team for an estimate and export details tailored to your country's requirements.


FAQ's of Michelson Interferometer (Bread Board Model) - Coherent Length of the Laser:


Q: How does the Michelson Interferometer measure the coherence length of lasers?

A: The Michelson Interferometer creates interference patterns by splitting and recombining a laser beam. By observing the distance over which the fringes remain visible, users can determine the coherence length accurately using the micrometer-adjusted movable mirrors.

Q: What lasers are compatible with this breadboard model Michelson Interferometer?

A: This model is engineered to be compatible with both He-Ne and diode lasers, making it suitable for a wide variety of physics laboratory applications.

Q: Where is the ideal site of application for this equipment?

A: The interferometer is specifically designed for laboratory use, particularly in educational and research settings where precise laser measurements are essential.

Q: What is the process for setting up the interferometer?

A: Setup involves mounting the optical components (mirrors, beam splitter, and laser) on the breadboard, aligning the laser beam, and using the micrometer screws for fine adjustments, all guided by the included instructional manual.

Q: How does the anti-vibration feature benefit laser measurement?

A: The anti-vibration rubber feet stabilize the breadboard, minimizing mechanical disturbances. This enhances measurement accuracy by maintaining clear interference patterns during observations.

Q: What is the estimated delivery time and export policy?

A: Delivery time depends on the destination and order volume, with express shipping available for urgent requirements. Export policies include sample provision and drop-off arrangements tailored to international clients.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory and Scientific Equipment Category

Lab Haskar

Lab Haskar

Minimum Order Quantity : 10 Units

Product Type : Lab Haskar

Color : White and Blue

Usage : Laboratory Material Testing

Control Mode : Digital Control

Response Time : 1 s

Fabry-Perot Etalon

Fabry-Perot Etalon

Minimum Order Quantity : 10 Units

Product Type : FabryPerot Etalon

Color : Black and Silver

Usage : Laboratory/Research

Control Mode : Manual

Response Time : Instantaneous (optical element)

PH Meter

PH Meter

Minimum Order Quantity : 10 Units

Product Type : PH Meter

Color : Red and Black

Usage : pH measurement in liquids

Control Mode : Manual

Response Time : < 20 seconds

Laminar-Air-Flow-Horizontal

Laminar-Air-Flow-Horizontal

Minimum Order Quantity : 10 Units

Product Type : LaminarAirFlow

Color : White

Usage : Laboratory aseptic technique

Control Mode : Automatic

Response Time : Instantaneous upon start